ELECTRICAL
MOTOR
CONDITION
MONITORING
We offer onsite AC/DC Motor Fault Diagnostic Services using Electrical Signature Analysis (ESA) and Motor Circuit Analysis (MCA).
De-energized Motor AC/DC Motor Testing (Offline):
Test the new or recently serviced motors from the vendor before installation or check the condition of the installed motor at the plant in de-energized mode:
In the de-energized mode we can test the motor to detect:
- Turn faults
- Coil Faults
- Ground faults
- Cable faults
- Connection Resistance
- Rotor Eccentricity
- Broken Rotor Bars
- Casting Voids
Detailed report will be submitted upon completion of the job.